会议专题

Open-circuit Fault Diagnosis and Fault-tolerant Control of IPMSM System

  The integrated mathematical model of an interior permanent magnet synchronous machine (IPMSM) system is set up suitable for healthy state,open-circuit fault state and fault-tolerant state in this paper.An on-line open-circuit fault diagnosis method is proposed,the fault-tolerant structure is set to connect the fault phase to the middle of DC link,considering that DC link voltage is not balanced,therefore,an optimized adaptive space vector pulse width SVPWM of four-switch three-phase inverters (FSTPI) under DC-link voltage ripple condition is presented to achieve the maximum torque per ampere (MTPA) control and flux weakening control of the IPMSM system under the fault-tolerant state.Based on the abovementioned research,system simulations are implemented and simulation results are given.

Kepeng Hao Hongmei Li

Department of Electrical Engineering, Hefei University of Technology, China

国际会议

第九届国际直线电机驱动与工业应用会议(LDIA2013)

杭州

英文

1-7

2013-07-07(万方平台首次上网日期,不代表论文的发表时间)