会议专题

Performance Analysis of Self-cleaning Hard Coating on Insulators after Trial Operation

  SCHC is a new kind of insulator coating designed to enhance the pollution flashover voltage,and more importantly,to reduce contamination accumulation on insulators.SCHC has good performance in laboratory,but its operating effect has not been studied.In this paper,sample insulators with SCHC coating having operated for a year are tested concerning its hydrophobicity,NSDD,ESDD,and voltage withstanding capability.The result shows that the hydrophobicity doesnt change after a years operation and contamination accumulation on SCHCs surface is much less than that on the RTVs surface.The SCHC has better performance than RTV overall and still needs to be improved in the future.

contamination pollution flashover self-cleaning self-cleaning hard coating (SCHC) RTV hydrophobicity leakage current

WANG Wei ZHANG Hua CHEN Can

Shanghai Municipal Electric Power Company Pudong Power Supply Company,No.111,Pudian Road,Pudong,Shan Graduate School at Shenzhen,Tsinghua University,Xili University Town,Nanshan District,Shenzhen,China

国际会议

2013 International Conference on Energy Research and Power Engineering(2013能源研究与电力工程国际会议)(ERPE2013)

郑州

英文

268-272

2013-05-24(万方平台首次上网日期,不代表论文的发表时间)