Research on Automatic Detection Method about Rotor Initial Position of Permanent Magnet Synchronous Motor
Its required to real-time detect rotor position for vector control of permanent magnet synchronous motor,the difference is initial rotor position angle between the output position signal of absolute rotary transformer and the position signal for park transformation,then it is necessary to get the initial position of the motor before the motor starts.Based on the characteristics of permanent magnet synchronous motor,a certain method about automatic detection of the initial position of a rotor is obtained.Compared with other methods,there are advantages such as simple calculation,small impact by the external and high detection accuracy.At last,the correctness of the method is verified by theory and experiment.
permanent magnet synchronous motor rotor initial position automatic test method absolute resolver
LI Bao ZHOU Guang-xu
Shandong Provincial Key Laboratory of Automotive Electronic Technology,Institute of Automation Shandong Academy of Sciences,Jinan Shandong 250014,China
国际会议
济南
英文
31-36