Effects on error of the component power flow by mounting deviation in pipes
A model between measuring error of component power flow in pipes and mounting deviation is developed.The proposed model shows that the component power flow is more prone to influenced by position deviation,and 5% deviation might result in 10% measuring error.Moreover,contrary to the total power flow,the error of the component power flow is also related to choice of grid origin and amplitude ratio of two component waves.
Power flow wave decomposition method measuring error position deviation angle deviation
Liu Yan Zhu Xian-ming Peng Wei-cai
National key laboratory on ship vibration & Noise,Wuhan,China;China Ship Development and Design Cent National key laboratory on ship vibration & Noise,Wuhan,China China Ship Development and Design Center,Wuhan,China