会议专题

Pipeline Leak Detection Based on Double Sensor Negative Pressure Wave

  Pipeline leak lead to huge economic losses and environmental pollution.Leak detection system based on single sensor negative pressure wave often causes false alarm.In this paper the double sensor method is adopted to exclude false alarm by determining the propagation direction of the pressure wave.In order to remove the inverse coherent interference caused by pump running,the phase difference of primary low frequency component is used to identify the sign of the time delay between the double sensors.The experiment shows the mothod is effective.

Time delay estimation Coherent interference Leak detection Negative pressure wave

Hou Chun-xia Zhang Er-hua

Engineering Training Center,Nanjing University of Science and Technology,Nanjing,210094,China School of Computer Science and Technology,Nanjing University of Science and Technology,Nanjing,21009

国际会议

2012 2nd International conference on Machinery Electronics and Control Engineering (2012年第二届国际机械电子与控制工程会议(ICMECE 2012))

济南

英文

1225-1228

2012-12-29(万方平台首次上网日期,不代表论文的发表时间)