会议专题

Ultrasonic test analysis of impact damage of polypropylene fiber mortar

  The method recommended by ACI Committee 544 was used in this paper.Drop hammer impact tests based on mortar specimens with different contents of polypropylene fiber were carried out.The Ultrasonic test is done before and after impacting.Under different drop hammer impact times,polypropylene fiber mortar specimens damage degree was evaluate based on ultrasonic velocity.The results show that the hammering number corresponding to the impact fracture of polypropylene fiber mortar is more than ordinary mortar.The ultrasonic velocity of all specimens decreased gradually during the process of hammering,but adding the right amount ofpolypropylene fibers can effectively slow down the rate of wave speed decline.

Mortar Polypropylene fiber Drop hammer impact Ultrasonic

CHEN Xiao Hong XUAN Wei Hong CHEN Yu Zhi

Jinling Institute of Technology, Nanjing 211169, China

国际会议

3rd International Conference on Frontiers of Manufacturing and Design Science(第三届制造与设计科学前沿国际会议(ICFMD))

香港