Ultrasonic test analysis of impact damage of polypropylene fiber mortar
The method recommended by ACI Committee 544 was used in this paper.Drop hammer impact tests based on mortar specimens with different contents of polypropylene fiber were carried out.The Ultrasonic test is done before and after impacting.Under different drop hammer impact times,polypropylene fiber mortar specimens damage degree was evaluate based on ultrasonic velocity.The results show that the hammering number corresponding to the impact fracture of polypropylene fiber mortar is more than ordinary mortar.The ultrasonic velocity of all specimens decreased gradually during the process of hammering,but adding the right amount ofpolypropylene fibers can effectively slow down the rate of wave speed decline.
Mortar Polypropylene fiber Drop hammer impact Ultrasonic
CHEN Xiao Hong XUAN Wei Hong CHEN Yu Zhi
Jinling Institute of Technology, Nanjing 211169, China
国际会议
香港
英文
324-328
2012-12-11(万方平台首次上网日期,不代表论文的发表时间)