Experimental Study of the Performance Test for the Infusion Monitoring System
Comparison with conventional manual adjustment to control the drop speed in clinical infusion,the infusion monitoring system can achieve much more high reliability and efficiency,and is easy to realize the automation of infusion.So the infusion monitoring system has been designed in the last papers.To test the designed system performance,some experiments are done.And the result show that under requirement of the system precision,the time consumption increase with the incensement of speed difference value; Comparing to the conventional PID controller,the fuzzy-PID controller can achieve high precision and little stabilizing time consumption.
infusion monitoring system system precision stabilizing time experimental study
XU Zhihui LI Weizhong XIAO Yongjun
HuBei Engineering University School of Physics and Electronic Information Engineering Xiaogan, China
国际会议
太原
英文
1705-1707
2012-12-08(万方平台首次上网日期,不代表论文的发表时间)