Calculation method of off-design power program for extraction and heating of turbine
The main distinguish between the heating units and the straight condensing unit is that they are appeared at the same time for the increasing of heating steam flow and the decreasing of generation power.The research object of this paper is conventional heating unit.The heating unit off-design power calculation program is developed by using Friuli Siegel formula and Excel VBA and based on the heating calculation program of straight condensing units.Finally,the generated output of units after extraction to heating can be calculated and the calculation errors of them are less than 0.5%; finally,the basic condition of 300 MW heating units can be assured through calculation.
turbine extraction for heating off-design power
Z.X.Lin L.Fu Z.Y.Zhao
Centre for Energy Saving Studies, Tsinghua University, Beijing, P.R.China Huadian Distributed Energy Engineering Technology Co., Ltd, Beijing, P.R.China
国际会议
香港
英文
121-125
2012-12-01(万方平台首次上网日期,不代表论文的发表时间)