会议专题

The numerical simulation and experimental research of Low-NOx burner retrofitting on a 420 T/h utility boiler

  The thermal test was carried out on a 420 T/h utility boiler of Xiaoshan power plant,the boiler can reach satisfactory performance and the thermal efficiency reaches 91.07%; Then a numerical simulation of the pulverized coal combustion was carried out on the basis of the test,by means of thermal aero dynamical field analysis and temperature field analysis,as well as the research for the pollutant,the numerical simulation results are in good agreement with the experiment,which provide good guidance for the Low-NOx burner transformation of the future large-scale station.

boiler burner NOx numerical simulation

Q.Zhang J.H.Zhou C.J.Zhao N.Ding J.R.Xu

State Key Laboratory of Clean Energy Utilization(Zhejiang University), Hangzhou, Zhejiang Province, Zhejiang Pyneo Co., Ltd., Hangzhou, China Hangzhou Dianzi University, Hangzhou, China

国际会议

2012 International Conference on Frontiers of Energy and Environmental Engineering(2012年第二届能源与环境工程前沿国际会议(ICFEEE2012))

香港

英文

184-187

2012-12-01(万方平台首次上网日期,不代表论文的发表时间)