会议专题

Study on operation parameters of capacitive deionization to reclaimed water treatment

  Active carbon fiber clothes are used as electrode materials.The paper has studied the main operating parameters which affect Capacitive Deionization (CDI) process,such as operating voltage,flow velocity of feed water,Hydraulic Retention Time (HRT) and regenerative method.Raw water is secondary treatment effluent of municipal sewage treatment plant.And the water quality has reached the discharge standard.The results show that it will achieve the best desalination effect under the operating conditions:operating voltage 1.7 Ⅴ,velocity 0.04 rn/min,HRT 120s,the regenerative way of short circuit connection.At the same time,the stability of the electrode materials and capacitive deionization performance are considerate by continuous capacitive deionization-desorption regeneration experiment and the test of cycle current-voltage curve,The experiment results show that capacitive deionization has great stability in dealing with reclaimed water desalination.

reclaimed water capacitive deionization Activated Carbon Fiber (ACF) conductivity

Z.L.Zhang Z.H.Zhang X.F.Guo Q.Zhang J.C.Wang

Department of Environmental Engineering, Tianjin Polytechnic University, Tianjin, China Department of Environmental Engineering, Tianjin Polytechnic University, Tianjin, China State Key La

国际会议

2012 International Conference on Frontiers of Energy and Environmental Engineering(2012年第二届能源与环境工程前沿国际会议(ICFEEE2012))

香港

英文

775-779

2012-12-01(万方平台首次上网日期,不代表论文的发表时间)