Sensitivity Analysis of 1000MW USC Units Shafting Torsional Vibration Based on ANSYS
To calculate a shafiings natural frequency of torsional vibration is one of the most important tasks in turbo-generators design, manufacture and frequency adjusting process.The sensitivity analysis of shafting structural parameters impact on the torsional vibration characteristics has important significance in reducing the amplitude of torsional vibration and ensuring the turbo-generators safe operation.In this paper, a 1000MW USC unit was taken as a research object to analyze the shaftings sensitivity to moment of inertia.
Finite element analysis Torsional vibration characteristics Moment of inertia
Shi Liu Cong Wang Bing Li Chang Chen Dan Mei Xie
Guangdong Electric Power Science Research Institute,Guangzhou 510080 School of Power and Mechanical Engineering,Wuhan University,Wuhan 430072 China
国际会议
上海
英文
162-165
2012-10-19(万方平台首次上网日期,不代表论文的发表时间)