会议专题

Crucial Torsional Modal Identify on Drive-train in a Wind Turbine

  The rotational frequency of large scale wind turbine is very low, so low order modal of drive-train in a horizontal-axis Wind turbine generator system (WTGS) needs special attention to avoid structural resonance.In this paper, with Lagranges equation, a three-mass drive-train dynamics of WTGS is modeled and analyzed.After comparing with the results by GHbladed4.1 and SIMPACK, we found that those results show little differences clearly.So the drive-train dynamics above is rational and the accurate analyses are fit to identify the crucial low order torsional modal of drive-train rapidly in WTGS.In addition, the anti-resonance frequency of the gear-train found by frequency response method can be very significant for vibration isolation of drive train in the wind turbine system.

Torsional modal Drive-train Wind turbine Lumped mass model

Hui Xin Li Fa Ming Wu Wen Li Dian Wang

CSR ZHUZHOU INSTITUTE CO.,LTD.CHINA College of Mechanical Engineering in Southwest Jiaotong University,CHINA

国际会议

the 2012 International Conference on Vibration, Structural Engineering and Measurement (2012年振动、结构工程与测量国际会议(ICVSEM2012))

上海

英文

275-280

2012-10-19(万方平台首次上网日期,不代表论文的发表时间)