会议专题

Structural Safety Monitoring during Retrofit of Shanghai Expo Puxi Entertainment Hall

  Shanghai Expo Puxi Entertainment Hall is reconstructed based on existing workshop building.To meet new function requirements of the hall, a structural column is removed and replaced with a jacking beam.A structural safety monitoring system is proposed and applied to evaluate the real-time structural state and ensure the structural safety.Vibrating wire sensors and FBG sensors are installed to monitor the stress of member of the space truss structure; ForesightTM series DSTS (Distributed Strain and Temperature Sensors) is installed to monitor the stress of the jacking beam.Results show that the structural safety monitoring system works stably.The safety monitoring system reflects the real-time behavior of the structure and controls the structural reconstruction safety effectively.

Existing Truss Structure Safety Monitoring Wireless Vibrating-wire sensors FBG sensors BOTDA sensor system

ZHAO Ming LIAO Jun

Tongji University,Department of Building Engineering,No.1239,Siping Rd,Shanghai,China Shanghai Geotechnical Investigations & Design Institute Co.,Ltd,No.111,Zhayin Rd,Shanghai,China

国际会议

the 2012 International Conference on Vibration, Structural Engineering and Measurement (2012年振动、结构工程与测量国际会议(ICVSEM2012))

上海

英文

1203-1208

2012-10-19(万方平台首次上网日期,不代表论文的发表时间)