Reduced Equivalent Static Wind Loads for Tall Buildings with Tuned Liquid Dampers

  The tuned liquid damper (TLD) is a proven and an increasingly popular auxiliary device for mitigating the dynamic effects induced by wind loading on tall buildings.As buildings become taller, lighter, and more flexible, there is a greater contribution from the dynamic component.The most reliable tool for assessing the dynamic component is wind tunnel testing.A boundary layer wind tunnel is capable of accurately calculating an equivalent static wind load (ESWL) acting on a building.The current study investigates the reduction in the ESWL of a lateral-torsional coupled building with a TLD system installed.The building is sensitive to torsion in the first two vibration modes.The current investigation uses three unique multi-modal TLD systems designed specifically for a lateral-torsional coupled building.The building ESWL is evaluated with the TLD systems using measurements from tests conducted at the Boundary Layer Wind Tunnel Laboratory at Western University.

Tall buildings Tuned liquid dampers Sloshing motion Vibration control Damping Serviceability Wind tunnel Tests

A.S.Ross A.A.El Damatty A.M.El Ansary

Department of Civil and Environmental Engineering,Western University,London,Ontario,Canada,N6A 5B9

国际会议

the 2012 International Conference on Vibration, Structural Engineering and Measurement (2012年振动、结构工程与测量国际会议(ICVSEM2012))

上海

英文

1218-1227

2012-10-19(万方平台首次上网日期,不代表论文的发表时间)