Impact of natural ventilation strategies on IAQ and energy consumption for residential building in Shenyang
In order to improve indoor air quality and reduce energy consumption of residential building,the paper focuses on measuring the concentration of CO2 and calculating the air change rate with different ventilation time to evaluate the performance of natural ventilation.Results show that it is difficult to meet the requirement of IAQ when the window is closed,unless open the window at a suitable period.Comparison of the C02 concentration and indoor air temperature under different conditions shows that the concentration of CO2 is greatly influenced by air change rate.
IAQ Energy consumption Air change rate Carbon dioxide
Huifen Zou Xiaozhen Cao Yingchao Fei Sheng Ye
School of Municipal and Environment Engineering,Shenyang Jianzhu University,Shenyang,Liaoning,China, Management School,Shenyang Jianzhu University,Shenyang,Liaoning,China,110168
国际会议
沈阳
英文
392-395