会议专题

Measuring method and sample size selection for the magnetostriction measurement of silicon steel

  Magnetostriction of silicon steel is the main cause of the noise of transformer,while its measuring method is argumentative.It was investigated in this paper the effect of sample size on the measuring stability and reproducibility using laser displacement meter method.It was found that for the sample size 100mm×500mm the measuring stability and repeatability are the best comparing to the size of 30mm×300mm,30mm× 100mm and 60mm× 100mm.For samples with the above for sizes cutting from the same sheet,the magnetostriction of 100mmx500mm size sample is the smallest.

magnetostriction silicon steel stability repeatability strain

Yechao Zhu Ningyuan Dang Xiaolong Guo Yong Lin

1National Engineering Research Center for Silicon Steel,Wuhan Iron &Steel Corporation,Wuhan Hubei 430080,China.

国际会议

the 2nd International Conference on Electronic & Mechanical Engineering and Information Technology (EMEIT-2012)(2012年电机工程与信息技术国际会议)

沈阳

英文

1283-1286

2012-09-26(万方平台首次上网日期,不代表论文的发表时间)