Discussion on Security Early Warning Mechanism of BF Hearth
Recently lots of blast furnaces (BFs) face the problem of hearth severe erosion even burnt out accidents.The campaign life of hearth has become the limiting factor for safe and high efficiency production of modern BFs.However,the early warning mechanism of hearth has not been clear due to the lack of system research.In this article,based on the heat transfer calculations,heat load and erosion monitoring for various BF hearths with different volume,structure and refractory,the features of heat load and erosion for different kind hearth are compared and analyzed.The primary detecting elements,software models,evaluating standards and warning methods are discussed.The early warning mechanism of modern BF hearth is proposed.
blast furnace hearth erosion heat load warning mechanism
ZHAO Hong-bo CHENG Shu-sen HUO Shou-feng
State Key Laboratory of Advanced Metallurgy,University of Science and Technology Beijing,100083,Chin School of Metallurgical and Ecological Engineering,University of Science and Technology Beijing,1000
国际会议
Asia Steel International conference 2012(第五届亚洲钢铁大会)
北京
英文
1-7
2012-09-23(万方平台首次上网日期,不代表论文的发表时间)