Comparison of Different Fault Detection Statistics Detectability in PCA
Detectability of the sensor fault detection system is the basic criteria for selecting of different fault detection statistics.PVR and CVR in MPCA are compared with T2H.The complementary among them is analyzed qualitatively.Results of power plant data simulation show that PVR and CVR in MPCA can improve sensor fault detection,but T2H is still better for some sensors.Combination of PVR,C VR and T2H can improve sensor fault detectability of PCA-based fault detection system.
process monitoring fault detection Principal component analysis
Tian Qiu Xiaojing Bai
Key Laboratory of Measurement and Control for Industry Process North China Electric Power University Beijing, China
国际会议
沈阳
英文
462-465