Consistency of High-g Acceleration sensor performance
Based on the designed,packaged high-g acceleration sensor in measuring demonstrated sensor performance between individuals have big difference,Researched this problem,through the analysis that the main reason of this problem appeared in the sensor package process of Die process.Through ANSYS simulation and experimental test on two aspects of the analysis the die adhesives amount of Die process is the high-g acceleration sensor in testing large performance differences were the main factors.Packaged high-g acceleration sensors with die process of quantitative die adhesive were designed and tested their performance.The result showed that,the simulation results were consistent with experimental results.
die adhesive high-g acceleration sensor consistency test ANSYS
Shi Yun-bo Zhang He Liu Jun Li Kejie
School of Mechatronic Engineering, Beijing Institute of Technology, 100081 ,China; Key Laboratory of Key Laboratory of Instrumentation Science & Dynamic Measurement(North University of China),Ministry School of Mechatronic Engineering, Beijing Institute of Technology, 100081 ,China
国际会议
香港
英文
101-104
2012-07-27(万方平台首次上网日期,不代表论文的发表时间)