会议专题

Optimal Design of an Ultrasonic Transducer in Rotary Ultrasonic Machining

  In this paper,an ultrasonic transducer is designed and optimized in order to reduce the error of resonance frequency and maximize the amplitude of the radiating tip.In order to get the basic dimensions of an ultrasonic transducer easily,resonance frequency equations are derived by using the traditional analytic method.Using ANSYS FEM software,we analyzed the vibration model of the transducer,including Modal Analysis and Harmonic Response Analysis.Studied how the length of two resonance rods affects the resonance frequency.By optimizing the dimensions of the ultrasonic transducer,the error of resonance frequency is reduced to 0.03%; the amplitude of the vibrating tip is up to 6.20μm.The optimal results show that the transducer designed in this paper has superior performance parameters and meets the requirements of machining.

Rotary ultrasonic machining Ultrasonic transducer Finite element analysis Optimal design

Fanchong Zeng Xianghui Zhang

College of Mechanical and Electrical Engineering North China University of Technology Beijing, China

国际会议

the 2012 International Conference on Frontiers of Mechanical Engineering and Materials Engineering (机械工程与材料工程国际会议())

香港

英文

352-355

2012-07-27(万方平台首次上网日期,不代表论文的发表时间)