Temperature Measurement and Simulation in Stainless Steel High-speed Grinding
Embedded K nickel chrome-nickel silicon thermocouple was used to measure the grinding temperature of stainless steel in the cases of high-speed grinding while machining SUS304 Stainless Steel with vitrified CBN wheels in high speed grinding conditions.The energy partition is approximately 7.7% by matching the measured temperature to the analytically computed temperature.3D FEM simulations for some typical grinding conditions are carried out.The error between the simulation analysis temperature results and the experimental results is approximately 3%on the grinding surface,and the error between the simulation analysis temperature results and the experimental results is approximately 10% below the grinding surface.
High-Speed Grinding Stainless Steel Energy Partition Grinding Temperature Simulation
Jun Yi Xiaomin Sheng Cangbo Feng
University of Hunan, Changsha,Hunan province,China National Engineering Research Center For High Efficiency Grinding, Changsha,Hunan province,China
国际会议
香港
英文
684-687