会议专题

Near-infrared Detecting Array for High Energy Laser Beam Diagnostics

  A near-infrared detecting array is developed combining photoelectric and calorimetric method together to measure CW beam profile of high energy lasers.Detailed structure and functional modules of this system are described.The system is widely sensitive to the wavelength range of 0.9~1.7μm and the power density range of W/cm2~kW/cm2.It has an effective detecting area of 22cm×22cm with a spatial resolution of 1.1 cm and a temporal resolution of 20ms.Experiments show that the uncertainty of the total energy measurement is 10% and the uncertainty of the power density distribution measurement is less than 15%.The measuring system has been successfully applied in the measurement for the far-field beam of high energy lasers.

High energy laser diagnostics Near-infrared detecting array Power density space-time distribution Beam parameter measurement

Lei Zhang Zhen-bao Wang Bi-bo Shao Peng-ling Yang Meng-meng Tao

State Key Laboratory of Laser Interaction with Matter,Northwest Institute of Nuclear Technology,P.O.Box 69-26.Xian 710024.P.R.China

国际会议

2012 International Meeting on Opto-Electronics Engineering and Materials Research(OEMR2012)(2012光电工程与材料国际会议)

沈阳

英文

156-159

2012-07-27(万方平台首次上网日期,不代表论文的发表时间)