Experimental Study on the Imaging of the Squeezed State Light with-4.93dB Quantum-noise Reduction at 1064 nm
A stable amplitude squeezed state light was generated by utilizing the optical parametric down-conversion (OPDC) technique based on periodically poled KTiOPO4(PPKTP) in an optical parametric oscillator (OPO) resonator.We observed a-4.93dB of squeezing in homodyne measurement.The imaging experiments of resolution target were conducted.It shown that the imaging resolution with squeezed state light as light source was 1.26 times that of the resolution with coherent light as light source.The squeezed state light was applied for imaging of real objects and we found that the imaging with squeezed light as light source is more distinct and has less distortion.
Squeezed states Resolution Imaging System
Baozhu Lu Siwen Bi Fei Feng Menghua Kang Fei Qin
State Key Laboratory of Transient Optics and Photonics,Xian Institute of Optics and Precision Mecha Department of Electrical and Computer Engineering,Villanova University,800 E.Lancaster Avenue,Villan
国际会议
沈阳
英文
439-444
2012-07-27(万方平台首次上网日期,不代表论文的发表时间)