会议专题

Supercritical CO2 Extraction of Rhizoma Atractylodis Macrocephalae

  An orthogonal array design was employed for optimizing the supercritical CO2 extraction of Rhizoma Atractylodis Macrocephalae.The extraction was performed at temperature from 40 to 60℃,pressure from 15 to 35MPa,extraction time varying from 30 to 90min and particle size spanning from 20 to 80 mesh.The results reflect that the extraction yield is more significantly influenced by the extraction time,pressure and particle size but less by temperature.The experiments show that the extraction yield obviously increases with increasing pressure,different from the literatures.In terms of the sample origin,a comparison shows that outstanding differences exist among the extraction yields from different sources.

Rhizoma Atractylodis Macrocephalae supercritical fluid extraction orthogonal array design extraction yield

HUANG Zhen SHI Xiao-Han LIU Shao-Fang JIANG Wei-Juan

Tianjin Key Laboratory of Food and Biotechnology, Tianjin University of Commerce, Tianjin 300134,PR Tianjin Key Laboratory of Food and Biotechnology, Tianjin University of Commerce, Tianjin 300134,PR

国际会议

2012 2nd International Symposium on Chemical Engineering and Material Properties(ISCEMP2012)(2012第二届化学工程与材料特性国际研讨会)

太原

英文

60-64

2012-06-23(万方平台首次上网日期,不代表论文的发表时间)