会议专题

COD Removal of Washing Water by Photodegradation

  Degradation of the wastewater of washing oil tanks after degreasing and minimal treatment by photocatalysis is studied by using a rotating photoreactor and TiO2 photocatalyst of Degussa P25.Effects of irradiation time and pH value on removing efficiency are investigated.The results show that the COD down to about 80mg/L can be achieved at the irradiation time of about 4-5 hours at mild pH valus.At the pH value from 1.5 to 3.2,the COD down to about 80mg/L can be achieved at the irradiation time less than 1 hour,and the COD down to about 20mg/L could be achieved at the irradiation time of about 4 hours at a pH value of about 3.2.

Photocatalysis pH value Washing water COD TiO2 nanoparticles

Qiaoling Zhang Zhijun Chen Ye Zhu Hongyong Xie

China Huanqiu Constructing & Engineering Co., Yinghuayuandongjie, ChaoyangDistrict, Beijing,China China Petroleum Pipeline Bureau Tianjin Design Institute, Tuanjie East Road,Dagang Haibin Street, Bi Shanghai Second Polytechinc Uinversity, 2360 Jinhai Road, Pudong 201209, China

国际会议

2012 2nd International Symposium on Chemical Engineering and Material Properties(ISCEMP2012)(2012第二届化学工程与材料特性国际研讨会)

太原

英文

415-418

2012-06-23(万方平台首次上网日期,不代表论文的发表时间)