New Polymeric Membrane Sensor Doped with N,N-bis(benzoin)-1,2-phenylenediamine for Selective Determination of Aluminum

  A new polymenc membrane sensor for A13+ based on bis(benzoin)-1,2-phenylenediamine as a neutral carrier was investigated.The proposed sensor exhibits a near-Nernstian response for A13+ over a wide linear range of 3.Ox10-7 to 1.Oxl0-1 mol/L,with a detection limit of 1.Ox10-7 mol/L and a slope of 19.7±0.3 mV/decade.The sensor displays a good selectivity toward A13+ over other cations in pH range of 2.5 t0 4.0.It has relatively fast response time (8 s) and can be used at least for 3 months without considerable divergence in potential.The response mechanism was discussed in view of the A.C.impedance technique.It was successfully used as an indicator electrode in the determination of aluminum m real samples.

Bis(benzoin)-1 2-phenylenediamine PVC membrane Al3+ sensor

Xinlu Liu Bin Xie Xunhai Pan Kangquan Qiao Ying Wang

College of Chemistry and Pharmaceutical,Sichuan University of Science and Engineering 643000,Zigong, Institute of Functional Material,Sichuan University of Science and Engineering,Zigong 643000,China College of bioengineering,Sichuan University of Science and Engineering,Zigong 643000,China