会议专题

Simulation Research and Analysis of an Improved Direct Torque Control System

  For enhancing operating efficiency of direct torque control system of salient-pole permanent magnetism synchronous machine,an improved direct torque control method which based on maximum torque per ampere(MTPA) is proposed.In the article firstly the new method theory inferential reasoning and the project short-cut method are elaborated.Then the simulation results which are comparison with conventional DTC are given using Matlab/Simulink.Finally the stable analysis and the dynamic analysis are given separately.The simulation and analysis show that the new method maintains t-me dynamic property of conventional DTC,but also may raise systems stable operating efficiency effectively.

Salient-pole PMSM Direct torque control (DTC) Maximum torque per ampere (MTPA) Efficiency

LANG Baohua YANG Jianhua LIU Weiguo

Xian Technological University,Xian,China Northwestern Polytechnical University,Xian,China

国际会议

2012 International Conference on Intelligent System and Applied Material(2012智能系统与应用材料国际会议)(GSAM2012)

太原

英文

650-654

2012-01-13(万方平台首次上网日期,不代表论文的发表时间)