SEISMIC RESPONSE ANALYSIS OF LARGE-SIZE LIQUID STORAGE TANKS CONSIDERING LIQUID-SOLID COUPLING
In order to maintain adequate strategic oil reserves to cope with oil crisis,the most economical and effective way is to increase the number of tanks and increase tank capacity,therefore,large storage tank are used more and more extensively.However,due to frequent earthquakes in recent years,the seismic safety of large storage tank is very important.In this paper,seismic response of large-size liquid storage tanks is analyzed,and liquid-solid coupling is considered in the model.The conclusions show that,after considering liquid-solid coupling,obvious elephant foot buckling phenomenon appears by considering liquid-solid coupling and it should be paid more attention in the seismic design.
Liquid storage tank liquid-solid coupling seismic response analysis elephant foot
Yuan Zhang Youhai Guan
College of Pipe & Civil Engineering, China University of Petroleum(Huadong), Qingdao 266580, P.R.China
国际会议
The Twelfth International Symposium on Structural Engineering (第十二届结构工程国际研讨会)
武汉
英文
1148-1150
2012-11-17(万方平台首次上网日期,不代表论文的发表时间)