会议专题

Discussion of Problems of Measurement Carbon on the inner Surface of inner Grooved Copper Tube by Infrared Absorption Method

  The inner surface carbon in the inner grooved copper tube was determined by tube furnace heating-infrared absorption method.Some factors which influenced the determination such as sample preparation and cleaning,flow rate,furnace constants,blank value,calibration constant were tested and optimized.The inner surface carbon of copper tube was released completely while the experiment temperature was chosen as 400~600℃ and the flow rate of oxygen was 750 mL/min.And the obtained integral calculus curve was ideal.The method has been applied to the determination of inner surface carbon in the inner grooved copper tube with carbon content of 0.24 mg/dm2.The result of the RSD was 3.7 %.And the recovery experiment through joining in synthesize carbon sample was carried on,the recovery was 98~ 103%.

Tube furnace Infrared absorption method Inner grooved copper tube Surface carbon

Huaibao Yuan Yuehong Li

Department of Environment Engineering and Chemistry,Luoyang Institute of Science and Technology,Luoyang,471023,P.R.China

国际会议

the 2012 2nd International Conference on Frontiers of Manufacturing Science and Measuring Technology (第二届制造科学与检测技术国际会议(ICFMM 2012))

西安

英文

1347-1350

2012-06-12(万方平台首次上网日期,不代表论文的发表时间)