Simulation Study on the Fluid-solid Coupled Heat Transfer of Cylinder Head
The 3D model of cylinder head and cooling water channel is built in the Pro / E software,the channel model is trimmed and divided to get the grid correspond with the computational requirements in the ICEM CFD,the fluid solving parameters and boundary conditions and other related information is set in the CFX software,the solid domain and the coupling parameter is set in the ANSYS MFX module,then the temperature field of cylinder head and waterways,wall convection heat transfer coefficient and other information is got.The overall designs rationality can be known from the temperature field,but between two outlets of the cylinder head,the highest temperature of the cooling water is 363K,it can be known from the flow of the cooling water that this part is not easy to be cooled,further improvement of the cylinder head structure should be made to improve the cooling effect of cylinder head.
Cylinder head Fluid-solid couple calculation Temperature field Finite element method
Mingyuan Zhang Lin Li Ming Yan
School of Mechanical Engineering, Shenyang University of Technology, Shenyang, China, 110870 School of Mechanical Engineering & Automation, Northeastern University, Shenyang, China, 110819
国际会议
厦门
英文
750-754
2012-01-04(万方平台首次上网日期,不代表论文的发表时间)