Research on Mechanism of Two Phase flow Lifting Pressure Equipment and Output Regulation
Taking into account the process and mechanism of lifting pressure were complex due to the condensation and shock wave,a one-dimensional theory model based on direct contact condensation is presented to analyze the lifting pressure character of steam-water two phase flow injector,and some key issues,such as inter-phase mass transfer computed by the average condensation heat transfer coefficient and phase volume fraction determined by steam plume,are discussed in detail.The regulations of discharge mass flow and output temperature are decoupling control according to the theory model,and the inlet water mass flow is to determine the output temperature,the variable throat section of steam nozzle is to determine the discharge mass flow.
injector two-phase flow direct contact condensation phase change steam plume
Gang Li Yunhong Huang Zhilin Lv Huilan Huang
College of Electrical Engineering, Guangxi University, Nanning 530004, China Guangxi Guilin Drainage Project Management Office, Guilin 541002, China
国际会议
厦门
英文
1619-1623
2012-01-04(万方平台首次上网日期,不代表论文的发表时间)