会议专题

Steady Sate Modeling of LHP and Analysis

  An ammonia-stainless steel steady state modeling of loop heat pipe was established,the impacts on the LHP operating temperature induced by alterable heat loads under 3 operating cases (the different position between evaporator and condenser,the changing of ambient temperature and the changing of heat sink temperature) were analyzed and conclusions were made.Changing the position between evaporator and condenser has a significant influence on the LHP operating temperature.Anti-gravity operation will reduce the performance of the LHP,this phenomenon is obviously in low heat load range.Further more,increasing of fluid pressure drop in the loop will induce decreasing of the LHP performance.The temperature difference between ambient and heat sink will influence the transition heat load (from variable conductance mode to fixed conductance mode),the bigger the temperature difference the higher the transition heat load.

LHP Steady State modeling Numerical Simulation

Yan CHEN Wei CHANG Shusheng ZHANG Chunsheng GUO

School of Energy and Power Engineering, Shandong Universicy, Jinan, Shandong, 250061, China Institute of Thermal Science and Technology, Shandong University, Jinan, Shandong, 250061, China

国际会议

the 2012 International Conference on Frontiers of Advanced Materials and Engineering Technology (2012年先进材料与工程技术国际会议(FAMET 2012))

厦门

英文

1834-1838

2012-01-04(万方平台首次上网日期,不代表论文的发表时间)