Steady Sate Modeling of LHP and Analysis
An ammonia-stainless steel steady state modeling of loop heat pipe was established,the impacts on the LHP operating temperature induced by alterable heat loads under 3 operating cases (the different position between evaporator and condenser,the changing of ambient temperature and the changing of heat sink temperature) were analyzed and conclusions were made.Changing the position between evaporator and condenser has a significant influence on the LHP operating temperature.Anti-gravity operation will reduce the performance of the LHP,this phenomenon is obviously in low heat load range.Further more,increasing of fluid pressure drop in the loop will induce decreasing of the LHP performance.The temperature difference between ambient and heat sink will influence the transition heat load (from variable conductance mode to fixed conductance mode),the bigger the temperature difference the higher the transition heat load.
LHP Steady State modeling Numerical Simulation
Yan CHEN Wei CHANG Shusheng ZHANG Chunsheng GUO
School of Energy and Power Engineering, Shandong Universicy, Jinan, Shandong, 250061, China Institute of Thermal Science and Technology, Shandong University, Jinan, Shandong, 250061, China
国际会议
厦门
英文
1834-1838
2012-01-04(万方平台首次上网日期,不代表论文的发表时间)