The Analysis and Testing of the Natural Frequency of Air-spring Precision Isolation Systems
In order to solve the discordance between the engineering calculated natural frequency and the experimental natural frequency of the air-spring precision isolation system,the dynamic models of the air-spring isolation system were established and the engineering calculated natural frequency was 1.28Hz based on an isolation system.Then,impact experiments were carried out in lab and the experimental natural frequency was 1.22Hz using FFT method.The relative error between the two was less than 5%,which reached the expectations,and the error sources were briefly analyzed.The results of the research in this paper have reference value in designing and manufacturing of the air-spring precision isolation systems.
Air-spring isolation system Natural frequency of the isolation system Engineering calculations of the natural frequency Analysis and testing of the natural frequency
Wen Zhang Jianlong Yin Liangbing Jin Dongsheng Li
College of Metrological Technology & Engineering,China Jiliang University,Hangzhou 310018,Peoples Republic of China