An cold experimental analysis of draught system with chain-grate stoker
The study of cold state testing and evaluation analysis were carried on the practical running chain-grate stoker,which has an air-supply system with air storehouse and airtrough,to study the air-distribution,air leakage,air tightness and air governing.The result shows that horizontal air distribution across the furnace and the air tightness of the components such as the air port (damper) and airtrough are good.However the air leakage is large because of the complex structure and the high demand of integrated air tightness either in the front or the back of the stoker.The cost of the stoker is high because of large quantity of machine work after casting and high demand of installation,thus the structure should be improved.
experimental study wind storehouse airtrough adjustment and distribution of draught
Zhi-ying Zhang Jia-hua Lu
Shanghai University of Engineering Science, 333 Long Teng Rd.201620 Shanghai, China
国际会议
重庆
英文
1236-1241
2011-06-23(万方平台首次上网日期,不代表论文的发表时间)