Temperature Measurement in Ultrasonic Vibration Mill-grinding of Ceramics with Infrared Thermovision
An experimental investigation is reported of the temperature measurement for ultrasonic vibration mill-grinding of silicon nitride with infrared thermovision.The effects of machining parameters such as spindle speed,feed speed,cutting depth on the surface temperature ofworkpiece were investigated and the reasons for the trend of temperature changes were analyzed.From the analyses,it indicates that infrared imager technology is suitable for temperature measurement in ultrasonic vibration mill-grinding of ceramics and tool wear has an important effect on the measurement results.
Ultrasonic Vibration Mill-grinding Temperature Infrared Imager Silicon Nitride
Guo Chao Qiao Ming Zhou
School of Mechanical and Electrical Engineering,Harbin Institute of Technology,Harbin 150001,PR Chin School of Mechanical and Electrical Engineering,Harbin Institute of Technology,Harbin 150001,PR Chin
国际会议