Non-sinusoidal Injection Control Strategy of Z-Source Inverter
The modulation strategy of injecting non-sinusoidal into reference voltage is presented in this paper.Z-source inductor current ripple and the relationship of voltage gain versus modulation index are analyzed in detail.Compared to simple boost control,the non-sinusoidal injection modulation strategy can obviously decreased the switching times,thus switching loss is cut down,and the voltage stress and Z-source inductor current ripple are obviously reduced.Theoretical analysis,simulation and experimental results are presented to demonstrate the features of the control.
Z-source inverter non-sinusoidal injection modulation strategy current ripple
Yang Zhou Xiao Ma
School of Mechanical and Electric Engineering,Guangzhou University,Guangzhou,510006 China
国际会议
广州
英文
1360-1366
2012-11-16(万方平台首次上网日期,不代表论文的发表时间)