Test Research on Mechanical Property of GFRP Bolt under Freeze-Thaw Cycle Conditions
In this paper,GFRP bolts in diameter of 25mm are tested through freeze-thaw cycle by 50,100 and 150 times to study their change law of appearance,weight,strength and elastic modulus.As reflected from the test results,after the freeze-thaw cycle,the appearance and weight of GFRP bolts are basically not changed.As the freeze-thaw cycle increases from 50 times to 100 times,the strength of bolts decreases gradually.After 50,100 and 150 times of freeze-thaw cycle,the ultimate tensile strength of bolt decreases by 2.82%,4.35% and 8.84%,respectively.During the process that the times of freeze-thaw cycle increase from 50 to 100,the elastic modulus of GFRP bolts grows gradually.After 50,100 and 150 times of freeze-thaw cycle,the elastic modulus increases by 1.42%,2.68% and 3.92%,respectively.The freeze-thaw cycle leads to embrittlement of GFRP materials and weakness of ductility,while not obviously.
GFRP Durability Anchoring Freeze-Thaw Cycle
Xiexing Tang Xiaoyong Luo Qi Sun Yachuan Kuang
School of civil engineering, Central South University, Changsha, Hunan, 410083, China
国际会议
广州
英文
689-694
2012-11-16(万方平台首次上网日期,不代表论文的发表时间)