会议专题

Air Leak Localization Method Based on Infrared Thermography Using Local Gray-entropy Difference Algorithm

  A novel air leak diagnosis and localization method for vessels is proposed.The tempreture field around the leak changes during air inflation and deflation.The changing phenomenon is acquired by thermal camera and the best detecting time is confirmed by temperature curves.Then a local gray-entropy difference algorithm is used to identify the leak area from infrared images captured during inflation and deflation.The gray information of local gray-entropy enhances the difference between leak area and non-leak area largely meanwhile the entropy information of local gray-entropy improves robustness perormance.Experiments verify that the leak localization method is effective and sensitive.

Leak Localization Infrared Thermography Local Gray-entropy

QIN Hehong WANG Tao FAN Wei

School of Automation,Beijing Institute of Technology,Beijing 100081,China

国际会议

the 16th International Conference on Fluid Dynamic and Mechanical & Electrical Control Engineering (第16届流体动力与机电控制工程国际学术会议 (FDMECE2012))

重庆

英文

200-203

2012-11-10(万方平台首次上网日期,不代表论文的发表时间)