A Small Size Dipole E-field Sensor for Calibration of Field Distribution in EMP Simulator
The calibration of field distribution in EMP simulator is discussed.A small size dipole sensor with built-in optic transmitter and fiber optic output connection is designed to measure field distribution in various points of the EMP simulator.Influence of the dipole sensor to the field distribution is first analyzed by numerical simulation and the actual field distribution is measured by the dipole.A correction coefficient is proposed based on the measurement results.The available working space in EMP simulator for sensor calibration is also defined.
EMP sensor calibration dipole antenna standard field
Li-hua Shi Rong-ren Si Qing Si Yan-xin Li
National Key Lab on Electromagnetic Environmental Effects and Electro-optical Engineering PLA University of Science and Technology Nanjing,210007,China