Numerical Simulation Study of OTA Anechoic Chamber Ripple Quality
MATLAB programs based on Geometrical Optics (GO)theory were used to calculate the standard uncertainty introduced by the ripple of Anechoic Chamber (AC) in OTA (Over The Air) test.The same method was also used to study the influence of various factors,including high directivity measurement antennas and high performance absorbers.In addition,we likewise found that support structures should be carefully designed to reduce their negative influence on OTA Test ripple quallity.
Anechoic Chamber OTA GO Ripple Test Uncertainty
Q.Z.Song Y.M.Shen J.Li N.Zhou Y.F.Xiong
The State Radio-monitoring-center Testing Center,SRTC,Beijing,China School of Electronic Engineering,Beijing University of Posts and Telecommunications,BUPT,Beijing,Chi International School,Beijing University of Posts and Telecommunications,BUPT,Beijing,China
国际会议
Asia-Pacific Conference on Environmental Electromagnetics (2012年第六届亚太环境电磁学会议(CEEM 2012))
上海
英文
403-406
2012-11-06(万方平台首次上网日期,不代表论文的发表时间)