会议专题

Relationship Between The Hole Diameter of Checkers in The Regenerative Chamber of Top Combustion Hot Blast Stove and Heat Exchange Capability

  This research has been carried out through top combustion type experimental stoves simulated at hot state.The capability of heat exchange for two kinds of checkers with different hole diameter have been compared.The results shows that checkers with hole diameter of 20mm have higher capability of heat exchange than that of checkers with hole diameter of 30mm,which is attributed to its more heat exchange area,small heat conduction thickness and big heat exchange coefficient.

LI Fuchao LI Jiantao DONG Hongqin SUN Gengchen CHEN Quanfeng

Zhengzhou Annec Industrial Co., Ltd, Zhengzhou, China

国际会议

The 6th International Symposium on Refractories (第六届国际耐火材料会议)

郑州

英文

246-249

2012-10-18(万方平台首次上网日期,不代表论文的发表时间)