会议专题

Application of BOTDA in Mass Concrete Temperature Monitoring

  In order to study the application of distributed optical fiber in temperature monitoring of mass concrete,monitoring instruments are embedded in pile cap to carry out the field experiment.The results show that the distributed temperature fiber which is based on brillouin optical time-domain analysis (BOTDA) has the superiority of anti-jamming,corrosion resistance,high precision and continuous measurement.It can accurately reflect the temperature change,effectively guide the construction,and play a positive role in preventing the emergence of concrete cracks caused by temperature change.Whats more,optical fiber has small volume and less influence on engineering,which make it have a good application prospect.

mass concrete temperature monitoring hydrate heat BOTDA

Juhua Xiong Lujie Wang Wenyong He Haofeng Xing

Department of Geotechnical Engineering, Tongji University, Shanghai 200092, China; Key Laboratory of Technical Center, Guizhou Transportation Planning Survey & Design Academe Co.Ltd, Guiyang 550001, Ch

国际会议

The International Conference on Civil Engineering, Architecture and Sustainable Infrastructure (2012土木建筑与可持续基础设施工程国际会议(ICCEASI2012))

郑州

英文

346-349

2012-09-22(万方平台首次上网日期,不代表论文的发表时间)