会议专题

Safety Analysis on the Structure of an Existing Metro Station Impacted by the Construction of an Adjacent Building

  Structural deformations of the existing metro station caused by adjacent building construction should be controlled strictly so as to keep the normal operation of the existing metro station and guarantee the safety of the station structure.Based on a foundation pit excavation and building project which is adjacent to an existing metro station in Beijing,a 3D finite element model of foundation pit,metro station and surrounding soil is established.Then,the structural deformations of the main body structure (rail area),the passageway and the fire fighting passageway in different construction stages are obtained.The control values of the station structure deformation during building construction process are proposed according to the calculation results.

metro station adjacent construction foundation excavation safety assessment

Liheng Ma Qinghuai Liang Liu Yifan He Mingran

Beijing Jiaotong University, Beijing, China

国际会议

The International Conference on Civil Engineering, Architecture and Sustainable Infrastructure (2012土木建筑与可持续基础设施工程国际会议(ICCEASI2012))

郑州

英文

777-782

2012-09-22(万方平台首次上网日期,不代表论文的发表时间)