会议专题

Study of a New High Frequency Moving Coil Linear Force Motor for Electro Hydraulic Servo Valve

  There are some problems in moving coil linear motor for Electro-hydraulic servo valve,such as big weight,small electromagnetic force,long response time and small bandwidth.After simulation analysis on permanent magnet placement and permanent magnet magnetization direction,it is found that distribution of magnetic field lines is uneven,magnetic flux density is low,and magnetic field lines are not vertical with the coil current direction.To solve these problems,a new type of linear force motor with 5 tings stack Halbach permanent magnet array structure is put forward.Through using the new structure,the weight and volume of motor can be reduced,and the electromagnetic force can be increased.Simulation results show that for the new structure,under the coil displacement change,the output electromagnetic force changes little and can maintain good linearity.Using permanent magnet with same volume,the electromagnetic force produced by new force motor is 2.5 times as it is produced by current motor.If the electromagnetic forces produced by two structures are same,the step response time of new type can be decreased of 14.3%,and the bandwidth can be improved to 2 times.

linear force motor servo valve Halbach Array electromagnetic force

Jun Hui Chen Feng Yu Yang

School of Energy and Power Engineering,Lanzhou University of Technology, No.287, Langongping Road., Qilihe District, lanzhou, Gansu, PRC,730050

国际会议

The First International Workshop on Hydraulic Equipment and Support Systems for Mining (第一届液压技术与矿山装备国际研讨会(IWHEM2012))

辽宁葫芦岛

英文

270-274

2012-08-07(万方平台首次上网日期,不代表论文的发表时间)