Seismic Response Spectrum Analysis of the Single Vertical Centrifugal Pump
A dynamic model of the single vertical centrifugal pump was established to avoid seismic disadvantageous direction towards the direction of continually occurring earthquake during the designing and the installing.Finite element method was used to analyse the single vertical centrifugal pump and educe the first 20 natural frequencies and vibration shapes.Response spectrum method was adopted to do earthquake analysis.Response spectrum was inputted from different directions for getting different displacements and loads.According to the results,models direction of 45°~75° should be located at the direction of continually occurring earthquake to avoid the maximum vibration.
Vertical centrifugal pump Dynamic characteristics Modal analysis Response spectrum
He Li Shibo Fu Qingrong Zhao Bangchun Wen
School of Mechanical Engineering and Automation, Northeastern University, Shenyang, Liaoning,110819, China
国际会议
台湾
英文
1450-1454
2011-12-11(万方平台首次上网日期,不代表论文的发表时间)