Error Analysis and Measurement of 6PUS-UPS Parallel Machine Tool

  Firstly,structure component of the 6PUS-UPS PMT (Parallel Machine Tool) was introduced.Secondly,errors during the machine tool debugging were analyzed and measured,and those determined by the 6PUS-UPS PMT structure character were focused on,including the clearance error between the slider and the guide way,the vibration error and the verticality error and so on.Lastly,the verticality error was measured using the digital display micrometer and the frame level,which has great influence on the 6PUS-UPS PMT precision.

Parallel Machine Tool Error Analysis Error Measurement Verticality Error Digital Display Micrometer Frame Level

Lianhe Guo Shuai Wang Shunpan Liang Yan Shi Yongsheng Zhao

Mechanical Engineering College, Yanshan University, Qinhuangdao, Hebei, China power Engineering Department, Hebei Engineering and Technical College, Cangzhou, Hebei,China