会议专题

Experimental Study of Energy Saving Effect of Building Envelope in Winter

  This paper presents an experimental study on the energy saving effect of building envelope in winter in Chongqing city.The basic cubicle was adopted for comparison.Experiments show that when energy saving measurements are applied in the external walls and windows,energy saving cubicle has an average energy efficiency rate of 32.68%,7.68% over the target value of the standard.The indoor temperature of the energy saving cubicle is higher than the basic ones.The internal surface temperature and the temperature difference between the exterior and interior of the insulation wall of the energy saving cubicle are both higher than that of the basic cubicle,the mean value is 1.28℃ and 1.90℃ respectively.And the temperature difference of the insulation glass is higher than that of the single glass,with a maximum value of 6.32℃.Daily simulation of the two cubicles is addressed by VisualDOE-4.0,the mean error between simulation and experiment is 16.16%,illustrating the effectivity and the accurateness of the VisualDOE-4.0.

Energy-saving building Experiment Energy efficiency Thermal performance

Houhua Wang Tao Zhang Qiulian Xiao

Faculty of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400045, P.R.China

国际会议

the Second International Conference on Frontiers of Manufacturing and Design Science(第二届制造与设计科学国际会议(ICFMD 2011))

台湾

英文

2741-2747

2011-12-11(万方平台首次上网日期,不代表论文的发表时间)