  To investigate the bond strength of different adhesive luting materials bond to zirconia ceramics.40 (30mm×5mm×5mm) Cercon Smart Ceramics samples were divided into groups:(1) glass-ionomer bonded (control group),(2) ClearfilTM Repair bonded,(3) Panavia F bonded,(4) Variolink N bonded.Tensile bond strength and shear bond strength were evaluated after 24h storage at 37℃ in distilled water.Each group had 10 samples for different test.Data were evaluated using ANOVA analysis (α=0.05).The experiment groups are statistically significant differences with control group (P<0.05).The shear bond strength of the Glass ionomer FX (I),the ClearfilTM Repair,Panavia F and Variolink N groups were 14.23±4.48 MPa,21.95±1.32 MPa,31.16±1.50 MPa and 43.54±1.97 MPa,separately.Comparisons among groups were significant differences (P<0.001).Variolink N bonded ceramics achieved highest tensile and shear bond strength.Different adhesive materials significantly influence the bond strength of zirconia ceramics.