会议专题

Study on the Structure of the Magnetic Fluid Damper

  Magnetic fluid damper is a kind of shock absorber which based on the principle of second-order buoyancy of magnetic fluid.In this paper,the structure of magnetic fluid damper is analyzed firstly,and then a variety of structural parameters on the damping effect are tested.Focusing on the different gasket angles in the damper,we found that gasket angles play a key role in the damper to influence on the damping effect.A corresponding model is put forward to analyze the inherent reasons.

Magnetic Fluid Damper Gasket Angle Damping Effect

Yao jie Li decai Zhang zhili Zhang junhui

School of Mechanical,Electronic and Control Engineering,Beijing Jiaotong University,Beijing China 100044

国际会议

The Seventh China International Conference on High-Performance Ceramics (第七届先进陶瓷国际研讨会(CICC-7))

厦门

英文

1474-1478

2011-11-04(万方平台首次上网日期,不代表论文的发表时间)