Improved heat dissipation for hot spots in MWT laminates

  The effect of leakage current in H-pattern and MWT laminates is investigated by thermal imaging.Degradation of the laminates was assessed by visual appearance and by the Ⅳ power output.The laminates were exposed to a reverse voltage for up to an hour.Depending on the leakage current,the laminates were locally heated.When the temperature reaches above the lamination temperature,severe damage occurs instantly.For similar leakage current,we observe a smaller temperature increase in MWT laminates than in H-pattern laminates.A possible mechanism for the reduced effect in MWT laminates is given.

Mark J.Jansen Lars A.G.Okel René A.Van Der Schilden Ingrid G.Romijn Bart J.Geerligs Bas B.Van Aken

ECN Solar Energy, PO Box 1, NL-1755 ZG Petten, the NETHERLANDS

国际会议

The 22nd International Photovoltaic Science and Engineering Conference (第22届国际光伏科学与工程会议)

杭州

英文

1-4

2012-11-05(万方平台首次上网日期,不代表论文的发表时间)